AMERICAN Ductile Iron Specials
Flange and Flare 90 Bends | Flare Castings
Flange and Flare 90° Bends
Flange and Flare 90 Bends | Flare Castings | To Top of Page
Short Radius |
|
Long Radius |
ADIP Table No. 7-12
Size
in. |
Pressure
Rating
psi |
T
in. |
C
in. |
Short Radius |
Long Radius |
A
in. |
B
in. |
Weight
lb |
A
in. |
B
in. |
Weight
lb |
| 30 |
250 |
1.03 |
38.75 |
25 |
36 |
1950 |
- |
- |
- |
| 36 |
250 |
1.15 |
46 |
28 |
38 |
2730 |
- |
- |
- |
| 42 |
250 |
1.28 |
53 |
31 |
35 |
3200 |
- |
- |
- |
| 48 |
250 |
1.42 |
59.5 |
34 |
46 |
5235 |
- |
- |
- |
| 54 |
250 |
.90* |
66.25 |
39 |
47.5 |
3540 |
- |
- |
- |
| 60 |
250 |
.94* |
73 |
43 |
54 |
4635 |
- |
- |
- |
| 64 |
** |
** |
** |
** |
** |
** |
- |
- |
- |
Notes:
* 54" and 60" castings have wall thicknesses that are per AWWA C153. All other wall thicknesses are per C100. See Table No. 7-3.
** Check AMERICAN for 64" Flare dimensions.
Since above fittings are not included in AWWA C110, A, B, and C dimensions above should be specified on engineering drawings.
Other joints can be furnished in lieu of flanges in some sizes.
See General Notes.
Flare+ Castings
Flange and Flare 90 Bends | Flare Castings | To Top of Page
Flange and Flare |
ADIP Table No. 7-13
Size
in. |
Pressure
Rating
psi |
Dimensions in Inches |
Weight in Lbs (Min.Length) |
| T |
L |
C |
Flg & Flare |
MJ & Flare |
| 4 |
250 |
0.52 |
8 |
9 |
40 |
- |
| 6 |
250 |
0.55 |
8 |
11 |
65 |
- |
| 8 |
250 |
0.6 |
10 |
13.5 |
105 |
- |
| 10 |
250 |
0.68 |
10 |
16 |
145 |
- |
| 12 |
250 |
0.75 |
12 |
19 |
210 |
- |
| 14 |
250 |
0.66 |
12 |
21 |
240 |
- |
| 16 |
250 |
0.7 |
16 |
23.5 |
310 |
- |
| 18 |
250 |
0.75 |
16 |
25 |
370 |
- |
| 20 |
250 |
0.8 |
18 |
27.5 |
435 |
- |
| 24 |
250 |
0.89 |
18 |
32 |
680 |
- |
MJ and Flare |
ADIP Table No. 7-13 cont.
Size
in. |
Pressure
Rating
psi |
Dimensions in Inches |
Weight in Lbs (Min.Length) |
| T |
L
Minimum |
L
Maximum |
C |
Flg & Flare |
MJ & Flare |
| 30 |
250 |
1.03 |
15 |
66 |
38.75 |
960 |
1080 |
| 36 |
250 |
1.15 |
14 |
66 |
46 |
1265 |
1435 |
| 42 |
250 |
1.28 |
12 |
72 |
53 |
1260 |
1430 |
| 48 |
250 |
1.42 |
18 |
72 |
59.5 |
2375 |
2625 |
| 54 |
250 |
.90* |
19 |
72 |
66.25 |
1475 |
- |
| 60 |
250 |
.94* |
21 |
72 |
73 |
1935 |
- |
| 64 |
** |
** |
** |
** |
** |
** |
- |
Notes:
+ This fitting is sometimes referred to as "bell mouth."
* 54" and 60" castings have wall thicknesses that are per AWWA C153. All other wall thicknesses are per AWWA C100. See Table No. 7-3.
** Check AMERICAN for 64" Flare dimensions.
Flare castings or fabrications can be furnished in a variety of lengths and with wall collars when specified. Flange or mechanical joint bell to be installed flush with the wall should be specified "tap for studs."
The addition of a wall collar to flare castings may affect the minimum length of the casting.
Other joints can be furnished in lieu of flanges or MJ bells in most sizes.
Since above fittings are not included in AWWA C110, L and C dimensions above should be specified on engineering drawings.
See General Notes.
|