Limited experimental data suggest that the frictional resistance term (Fs) should be multiplied by a factor of 0.70 for pipe encased in polyethylene film.

|
|
Horizontal Bend |
|
Ff =Fs; For standard asphaltic coated pipe Ff = 0.7 Fs; For polyethylene encased pipe |
INT Dimensions and Unit Weights of Pipe and Water
| DIMENSIONS AND UNIT WEIGHTS OF PIPE AND WATER |
Nominal
Pipe Size
(mm) |
Class |
Pipe Outside
Diameter, D'
(m) |
Cross-Section
Area of Pipe
A
(cm2) |
Wp
(kg/m) |
Ww
(kg/m) |
Wp+Ww
(kg/m) |
| 100 |
K9 |
0.119 |
110 |
16 |
7 |
23 |
| 150 |
K9 |
0.171 |
227 |
24 |
18 |
42 |
| 200 |
K9 |
0.222 |
386 |
33 |
33 |
66 |
| 250 |
K9 |
0.274 |
589 |
42 |
51 |
93 |
| 300 |
K9 |
0.326 |
835 |
54 |
73 |
127 |
| 350 |
K9 |
0.378 |
1122 |
67 |
98 |
165 |
| 400 |
K9 |
0.43 |
1446 |
80 |
128 |
208 |
| 450 |
K9 |
0.482 |
1810 |
95 |
161 |
256 |
| 500 |
K9 |
0.533 |
2222 |
110 |
199 |
309 |
| 600 |
K9 |
0.634 |
3166 |
144 |
287 |
431 |
| 700 |
K9 |
0.738 |
4277 |
183 |
390 |
573 |
| 800 |
K9 |
0.844 |
5582 |
228 |
512 |
740 |
| 900 |
K9 |
0.945 |
7012 |
274 |
647 |
921 |
| 1000 |
K9 |
1.048 |
8625 |
326 |
799 |
1125 |
| 1200 |
K9 |
1.256 |
12368 |
446 |
1155 |
1601 |
| 1400 |
K9 |
1.463 |
16791 |
580 |
1604 |
2184 |
| 1500 |
K9 |
1.567 |
19241 |
661 |
1840 |
2501 |
| 1600 |
K9 |
1.667 |
21849 |
743 |
2094 |
2837 |
|